This is an old revision of the document!
Almost all GPU servers (astra 2→9) are located in this room, where each server is provided whith redundant power supply and fast internet access and enough cool air. Recently (03/2018) the new storage server sto3 moved there as well and the configuration looks like this:
rack | number |
---|---|
rack | 4 |
device | rack location |
Netgear 10GB switch | U12 |
astra-tesla-9 | U10-11 |
sto3 | U5-9 |
astra-tesla5-9 | U1-4 |
Tesla-9 and sto3 are connected via 10GB ethernet NIC's and the Netgear switch. Later on we can connect the other tesla's as well to t his fast 10GB switch. This combination gives fast access to data stored on the storage server (e.g. uploaded data from partners), for calculations on the GPU server, as well as output data on the storage server, provided the given mount points over the 10GB switch are used.
root@sto3:~# ethtool ens5f1 Settings for ens5f1: Supported ports: [ TP ] Supported link modes: 1000baseT/Full 10000baseT/Full Supported pause frame use: No Supports auto-negotiation: Yes Advertised link modes: 100baseT/Full 1000baseT/Full 10000baseT/Full Advertised pause frame use: No Advertised auto-negotiation: Yes Speed: 10000Mb/s Duplex: Full Port: Twisted Pair PHYAD: 0 Transceiver: external Auto-negotiation: on MDI-X: Unknown Supports Wake-on: d Wake-on: d Current message level: 0x00000007 (7) drv probe link Link detected: yes
For astra-9 →
[vlab@astra-tesla-9 ~]$ ethtool ens1f1 Settings for ens1f1: Supported ports: [ TP ] Supported link modes: 1000baseT/Full 10000baseT/Full Supported pause frame use: No Supports auto-negotiation: Yes Advertised link modes: 100baseT/Full 1000baseT/Full 10000baseT/Full Advertised pause frame use: No Advertised auto-negotiation: Yes Speed: 10000Mb/s Duplex: Full Port: Twisted Pair PHYAD: 0 Transceiver: external Auto-negotiation: on MDI-X: Unknown Cannot get wake-on-lan settings: Operation not permitted Current message level: 0x00000007 (7) drv probe link Link detected: yes