CDE D2 serverroom

Almost all GPU servers (astra 2→9) are located in this room, where each server is provided whith redundant power supply and fast internet access and enough cool air. Recently (03/2018) the new storage server sto3 moved there as well and the configuration looks like this:

rack number
rack 4
device rack location
Netgear 10GB switch U12
astra-tesla-9 U10-11
sto3 U5-9
astra-tesla5-9 U1-4

Tesla-9 and sto3 are connected via 10GB ethernet NIC's and the Netgear switch. Later on we can connect the other tesla's as well to t his fast 10GB switch. This combination gives fast access to data stored on the storage server (e.g. uploaded data from partners), for calculations on the GPU server, as well as output data on the storage server, provided the given mount points over the 10GB switch are used.

root@sto3:~# ethtool ens5f1 | grep Speed
        Speed: 10000Mb/s

For astra-9 →

[vlab@astra-tesla-9 ~]$ sudo ethtool ens1f1 | grep Speed
        Speed: 10000Mb/s

10GB switch

To use these 10GB NIC cards, we need a switch with the same capacity. →